Technical Parameter
Base Layer Parameter
| Item | Condition | FL (Vulcanized Rubber Type) | FF (Non-Vulcanized Rubber Type) | FS1 (Resin Type) | FS2 (Resin Type) |
| Tensile Strength/(N/cm) | At 23℃ ≥ | 80 | 60 | 100 | 60 |
| At 60℃ ≥ | 30 | 20 | 40 | 30 | |
| Elongation at Break/% | At 23℃ ≥ | 300 | 250 | 150 | 400 |
| At -20℃ ≥ | 150 | 50 | - | 300 | |
| Tearing Strength/N | ≥ | 40 | 20 | 20 | 50 |
| Impermeability | 0.3 MPa, 30 min | No Leakage | No Leakage | No Leakage | No Leakage |
| Low-Temperature Flexibility | - | No Crack at -35℃ | No Crack at -20℃ | No Crack at -30℃ | No Crack at -20℃ |
Self-adhesive Layer Parameter
| Item | Condition | Index |
|---|---|---|
| Low-Temperature Flexibility | - | No Crack at -25℃ |
| Holding Adhesion/min | - | ≥20 |
| Peel Strength/(N/mm) | Standard Condition | |
| Sheet to Sheet | ≥0.8 | |
| Sheet to Aluminum Plate | ≥1.0 | |
| Sheet to Cement Mortar Plate | ≥1.0 | |
| After Water Immersion | ||
| Sheet to Sheet | ≥1.0 | |
| Sheet to Aluminum Plate | ≥1.2 | |
| Sheet to Cement Mortar Plate | ≥1.2 |
Self-adhesive Waterproof Borad Guidelines
- Substrate Requirements:
The waterproofing substrate must be structurally sound and level, free from protruding sharp edges, surface pits and dusting. The surface must be clean and dry, with all transitions formed into 50mm-radius arcs. The substrate moisture content must exhibit no visible moisture.
- Operation Sequence:
(1) Substrate Surface Cleaning & Repair
(2)Application of Compatible Primer
(3)Application of Compatible Primer
(4)Positioning & Baseline Marking
(5)Installation of Self-adhesive Waterproof Membrane
(6)Roller Compaction & Air Expulsion
(7)Edge Sealing & Overlapping
(8)Inspection & Acceptance
(9)Protective Layer Construction
- Installation Details:
- On horizonal surfaces: From the farthest point inward
- On vertical surfaces: Top-down
- Wall-to-Floor Transitions: 50mm-radius arcs surface for structural transition